Installation, Operation & Maintenance
Instructions
Please leave this instruction booklet with the home owner as it contains
important guarantee, maintenance and safety information
Read this manual carefully before commencing installation.
This manual covers the following products:
Monsoon U1.5 bar Twin
Pt. No. 46505
Monsoon U2.0 bar Twin
Pt. No. 46480
Monsoon U3.0 bar Twin
Pt. No. 46410
Monsoon U4.0 bar Twin
Pt. No. 46411
Monsoon U4.5 bar Twin
Pt. No. 46412
FOR POSITIVE OR NEGATIVE HEAD APPLICATIONS
CE compliant product
Vedere la pagina 0
1 2 3 4 5 6 ... 27 28

Sommario

Pagina 1 - Instructions

Installation, Operation & Maintenance InstructionsPlease leave this instruction booklet with the home owner as it contains important guarantee, ma

Pagina 2 - CONTENTS Page

- 10 -Cont ...3.13 Typical Low Level Installation: In certain installations it may be necessary to install a 90° bend on the inlet or outlet co

Pagina 3

- 11 -Cont ...4.16 Earthing: This appliance must be earthed via the supply cord, which must be correctly connected to the earth point located in

Pagina 4

- 12 - The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. The wire which is

Pagina 5 - 2 LOCATION - GENERAL

- 13 -Cont ... To enable correct assembly of the cable gland the ‘O’-ring (Fig. 12 item 1) must be placed over the cable before the clamping ins

Pagina 6 - 2 PUMP LOCATION - TWIN PUMP

- 14 -5 COMMISSIONING5.11 System Flushing: This pump incorporates push-in connectors and plastic components that must not come into contact with

Pagina 7

- 15 -Cont ...5.14 Starting: a) Ensure all outlets are closed, turn power supply ‘on’ - pump will start, pressurise the system then stop. b

Pagina 8 - 3 PUMP CONNECTIONS

- 16 -Cont ...6 MAINTENANCE6.11 Turn off water supplies to the pump and release pressure by opening water outlets before attempting maintenance.

Pagina 9

- 17 -Cont ...6.14 Pressure vessel: Should ever the need arise for the vessel to have its air charge checked or replenished, it should be carried

Pagina 10

- 18 -Stuart Turner reserve the right to amend the specification in line with its policy of continuous development of its products.Note: For informat

Pagina 11 - 4 ELECTRICAL INSTALLATION

- 19 -8 TROUBLE SHOOTING GUIDESymptoms Probable Cause Recommended ActionPump will not start. Electrical supply. Check power supply.Check fuse (see fu

Pagina 12 - Fig. 11

- 2 -PRODUCT DESCRIPTIONElectric motor driven twin ended peripheral pumps complete with an automatic control system, consisting of flow switches, pres

Pagina 13 - Cont

- 20 -Cont ...8.11 Dry Run Protection: This pump is fitted with a PCB that will detect the following fault conditions:  Dry running caused by wat

Pagina 14 - 5 COMMISSIONING

- 21 -Cont ... IMPORTANT – Ensure there is no contact with any of the internal parts of the terminal box.  Briefly reconnect the mains power su

Pagina 15

- 22 -Cont ...8.14 Flow Switch Circuit Test:1. First confirm visually that the flow switch reed clamps have not been dislodged during handling

Pagina 16 - 6 MAINTENANCE

- 23 -Cont ...9 THE MONSOON GUARANTEECongratulations on purchasing a Stuart Turner pump. We are confident this pump will provide many years of troubl

Pagina 17 - Schrader valve

- 24 -In the event of a claim please telephone ‘Pump Assist’ or return the pump and flexible hoses with the accessories removed e.g pipes etc. If you

Pagina 20

- 27 -NOTES

Pagina 21 - Retaining screws x 4

Stuart Turner Ltd, Henley-on-Thames, Oxfordshire RG9 2AD ENGLAND Tel: +44 (0) 1491 572655, Fax: +44 (0) 1491 573704email: pumps@stuart-turn

Pagina 22

- 3 -Cont ...CHECKLISTItemDescription QtyItemDescription QtyPump 1 Tank & sealing washers 1Hose & sealing washer 4ACBYour product may vary sli

Pagina 23 - EXTEND YOUR PUMP GUARANTEE

- 4 -Cont ...1 READ BEFORE COMMENCING PUMP INSTALLATIONA. Water storage capacity.1.11 The hot and cold water storage capacity must be sufficient to

Pagina 24 - 0844 98 000 97

- 5 -Cont ...2 LOCATION - GENERAL2.11 Access: For emergencies and maintenance the pump must be easily accessible.2.12 Protection: The pump must

Pagina 25

- 6 -2.26 Non-preferred pump location: If it is not possible to locate the pump in the preferred area due to site limitations and it is necessar

Pagina 26

- 7 -Cont ...Cold water connection:2.27 The cold water supply: The supply must be air free and have a dedicated connection to the tank which sh

Pagina 27

- 8 -Cont ...3 PUMP CONNECTIONS  Do not use stainless steel, chrome or nickel plated pipe with the flexible hose push-in plumbing connections.

Pagina 28 - Business Development Director

- 9 -Cont ...3.12 Hose to pipework:1. The hoses are fitted with plastic push-in connectors, which must only be connected with the following: a